Get a Quote

How Rotavapor Files

Rotary Evaporators Fisher Scientific.

BUCHI Rotavapor™ R300 Rotary Evaporator with ControllerThe R300 meets the highest expectations in convenience and versatilityIts modular design allows extension of the Rotavapor™ R300 to a fully integrated system where a central interface regulates each component.

3 Order code Choose the configuration according to your needs Rotavapor 174 R300 1 If glass assembly E CR or BY is required for Glass Assembly select N for Standard Joint select either 1 or 2 and for Protective Coating select 0 vapor duct and evaporating flask are includedGlass assembly E CR or BY need to be ordered separately.

1 Glass assembly With a vacuum rotary evaporator you can carry out singlestage distillation runs quickly and gentlyThe evaporation capacity of a rotary evaporator is about 4 times greater than that of a conventional static distillation apparatusHeat transmission in the heating bath as well as inside the flask is.

Rotavapor R300 Technical data sheet.

B252chi rotavapor r114 manual B252chi rotavapor r 114 operation manual.

Buchi Rotavapor Evaporator Vacuum Controller R134 with B481 Water Bath and GlasswareThis is a preowned BUCHI Rotavapor R134 with the water bath B481 and all the glassware pictured all in very good conditionThe Rotavapor is designed and built for laboratory service.

Buchi Rotavapor R114 Rotary Evaporator 5 to 240 rpm Made in Switzerland.

Dec 08 2021nbsp018332In a rotary evaporator the motor rotates the evaporation flask or vial containing the user’s sampleVapor duct is the axis for sample rotation and is a vacuumtight conduit for the vapor being drawn off the sampleThe vacuum system substantially reduces the pressure within the evaporator system.

Dec 16 2019nbsp018332The video below illustrates how this is done but here are the general steps Fill a small to mediumsized twoneck roundbottom flask about halfway with acetoneA threeneck flask with a stopperConnect one socket to the rotovap where the evaporation flask would usually go.

Evaporar el disolvente mediante su destilaci243n en un rotavapor a 30 186C al vac237oEvaporate the solvent by distillation on a rotary evaporator at 30 186C under vacuum100 alcohol de pureza se recoger225n en matraz de rotavapor colecci243n100 purity alcohol will be collected in rotary evaporator collection flask.

In contrast to previous generation of B252chi Rotavapor systems the new B252chi Rotavapor R200205 needs only one sealing system which is suitable for distillations under refluxAll materials which come into contact with chemicals are made of glass PTFE and ETFE.

Instructions for Using Buchi Rotavapor 1Turn on the water supply to the aspirator pump the tap is labeled so a slow but steady stream of water comes out of the overflow port on the side of the blue tank that is part of the vacuum aspirator pump unit then turn on the power switch to start the vacuum aspirator pump motor.

Jan 18 2017nbsp018332The rotary evaporator principle is that the boiling points of liquids reduces on decreasing their pressure allowing solvents to be vaporized at much lower temperatures than their boiling points at normal pressure.

Oct 22 2021nbsp018332The R210215 Advanced combines the Rotavapor with the Vacuum Controller V850 and is suitable for all standard Rotavapor tasksThe R210215 Professional includes the Vacuum Controller V855 and the stage probe for auto distillation for condenser types V and SThe appeal of this arrangement is its versatility.

Operation Manual Original Rotavapor174 R250 Pro 11594225 Publication date 032022 Version B B220CHI Labortechnik AG Meierseggstrasse 40 Postfach CH9230 Flawil 1 EMail qualitybuchi.

Operation manual Rotavapor R250 Pro enProduct Brochure NIROnline Multipoint System enTechnical Data Sheet Multipoint SystemB290 Pre Installation Checklist.

Operation Manual Rotavapor174 R173100 760 Safety2 Intended use21 The Rotavapor174 R173100 is intended for evaporating and condensing solvents.

Rotavapor R250 4 Putting into Operation 4 Putting into Operation The danger zone around the Rotavapor R250 can extend outward by up to 10 mWhen working inside this danger zone there is a risk of damaging the glass parts which could cause them to implode1 Installation Location Always set the unit up on a clean stable and flat surface.

Rotavapor174 R100 Technical data sheet The Rotavapor174 R100 is a highquality rotary evaporator to meet the essential needs in clas sical laboratory applicationsIt is capable of a manually adjustable rotation speed of 20 to 280 rpm and equipped with an action jack lift for manual lifting of the evaporating flask.

Rotavapor174 R220 Pro Technical data sheet The Rotavapor 174 R220 Pro is designed to fulfill a wide range of distillation applications in the in dustrial environmentSafety robustness and easy handling are the key benefits of this system.

Youre currently reading page 1 Page 2 Page Next ShowR300 Support ring part of a valve unitAdd to Wish List Add to CompareR300 Flange screwed connection for glass assembly VCA.

The purpose of using the rotary evaporatorWe use the rotary evaporator rotovap for two main purposes 1To concentrate nonvolatile components in a mixture for example concentrating the purest and freshest flavors from a blood orange by removing the water 2To extract the volatile aroma and flavor molecules from mixtures gently and at.

The Rotavapor174 R300 meets the highest expectations of convenience and versatility in rotary evaporationIts modular design allows the R300 to be extended to a fully integrated system where a central interface regulates each componentEvaporating flask size 50 – 5000 mLLift mechanism Manual or automaticTemperature range 20 – 220 176C.

The setup of a rotary evaporator The first step is to pour the solvent mixture and the compound you want to work on in a round bottom flaskIt is advisable to fill the flask less than a half if you want to get the desired results.

These operating instructions describe the Rotavapor174 R100 at the time suppliedThey are an integral part of the product and contain important information that is necessary for safe operation and maintenanceThese operating instructions apply to all variants of the Rotavapor174 R100 and are intended primarily for laboratory staff.

Get in Touch

Need more additional information or queries? We are here to help. Please fill in the form below to get in touch.